Naar homepage
Generating Confidence
Products > Battery Switches > DC Charging Relay 12V

DC Charging Relay 12V

Battery Switches

Article Number
50214735DC Charging Relay 12V
General
Model type 12 VDC Magnetic Latch Charging relay, link batteries
Circuit type Bi stable ACR
Input
Battery input 2
Switch Positions 2
Manual overide Locked off/on
I 10 Cranking rating 10 sec 2500A
I 60 Cranking rating 1 min 1100A
I 300 Cintermittent rating 5 min 700A
I C continue rating 500A
Vmno Voltage maxium Operation 32VDC
Control Circuit Voltage 10.1..16.5VDC
Operatiuon current continous < 40mA
Operation current when charging < 7 A
Remote Control switch when charging 100 mA
Automatically combines battery banks when senses voltage levels are: Above 13.5 for 30 sec. / Above 13.0 for 90 sec.
Automatically isolates battery banks when sensed voltage levels are: Below 9.6V (undervoltage lockout) / Below 12.35V for 10 sec. / Below 25.5V for 30 sec. / Above 16.2V (undervoltage lockout)
General
Ambient operation temperature -20ºC … +40ºC
Storage temperature -25ºC … +85ºC
Operating humidity 95%, non condens
Live current switching 100.000 cyles
Mechanical
Connections terminal stud M10 (3/8’-.16)
Connections stud lenght 23 mm
Maximum terminal Stud Torque 15.5 NM (140 in-lb)
Terminal material tin-plated copper
Enclosure width 95.25 mm
Enclosure height 138.94 mm
Enclosure depth 51.56 mm
Weight 0.8 kg
Drilling mounting centers 114.3mm * 76.20mm
Mounting srews 4 mm
Ingress Protection Class IP66
Enclosure Colour RAL9011 Graphite Black
Cable clearance 28.4 mm (1.12’)
Ignition Protection SA J1171
Markings CE, Iso 8846

 