Naar homepage
Generating Confidence
Products > Sinewave Inverter / Charger > WPC 48 V / 4000 W - 50 A

WPC 48 V / 4000 W - 50 A

Sinewave Inverter / Charger

Article Number
6020100360201003 WPC 48 V / 4000 W (10500 VA max) 50 A - 230 V / 50-60 Hz
60201004WPC 48 V / 8000 W (21000 VA max) 100 A - 230 V / 50 Hz = 2 x WPC 48 V / 4000 W stack
INVERTER SPECIFICATIONS
Nominal battery voltage 48 VDC
Input voltage range 38..68 VDC
Continuous power @ 25°C 3500 VA
Power 30 min. @ 25°C 4000 VA
Power 5 sec. @ 25°C 10500 VA
Maximum load Up to short-circuit (fully protected)
Maximum a-symmetric load Up to continuous power
Load detection (stand-by) 2 to 25 W (AES) Automatic Enable System
Power factor 0.1-1
Efficiency (@ full load) 96%
Consumption OFF/Stand-by/ON 1.8 W / 2.1 W / 14 W
Output voltage Pure sine wave 230 VAC (+/- 2%)
Output frequency 50 Hz / 60 Hz (1) +/- 0.05% (crystal controlled)
Harmonic distortion (voltage) <2% THD
Overload and short-circuit protection Automatic disconnection with 3 time restart attempt
Overheat protection Warning before shut-off with automatic restart
BATTERY CHARGER SPECIFICATIONS
Charge Characteristic 6-step Bulk-Absorption-Floating-Equalization-reduced floating-periodic absorption. Number of steps, thresholds,return amps completely adjustable.
Maximum charging current 50 A
Temperature compensation With Whisper temperature sensor WPC-BTS
Power Factor Correction (PFC) EN 61000-3-2
Input voltage range 150 to 250 VAC
Input frequency range 45 to 65 Hz
Input current max. (transfer relay) / Output current max. 30 A / 47 A
Transfer time <15 ms
GENERAL DATA
Local user interface WPC-4000-48*
Weight 28 kg
Dimension hxwxd [mm] 510 x 330 x 150 mm
Protection degree IP21
Color RAL 9003
Conformity Directive EMC 2004/108/EC : EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, 62040-2. Low voltage directive 2006/95/EC : EN 62040-1-1, EN 50091-2, EN 60950-1
Operating temperature range -20..+40°C, derating to 55°C
Relative humidity (operational) 95% without condensation
Ventilation Forced from 45°C
Warranty 2 years
Acoustic level <40 dB / <45 dB (without/with ventilation)
WPC ACCESOIRES
60201080 WPC-RCC Remote Combi Control
60201082 WPC-BSI 500 Battery Status Interface
60201084 WPC-RS232 Serial Interface
60201086 WPC-BTS Battery Temperature Sensor

 

Where to buy