Isotransformer 2000 – 120 / 240 V | 50 / 60 Hz

Whisperpower isolation transformers offer optimal safety by eliminating shock hazards to life beings on board and in the water adjacent to a boat, by preventing AC current flow from the shore to metal objects on a boat, thereby stopping nuisance tripping of RCD (residual current device) or GFCI (ground fault circuit interrupt) systems when on shore power.

Demander un devis
  • Safety by galvanic isolation of AC power
  • Prevention of galvanic corrosion
  • Includes circuit breaker on primary
  • Low noise, low weight toroidal transformer with vibration isolated mounting
  • Global shore power 230 V or 120 V input, 50 or 60 Hz
  • Configurable for 230 V, 120 V or Split Phase 120+120 V ship supply output

Our isolation transformers also reduce possible galvanic corrosion of hulls, propellers, or other metal parts under a ship, eliminating the need for installing galvanic isolators, sacrificial anodes and polarity alarms. By preventing DC currents traveling between a shore ground connection and metal parts of a ship, no current flow path between two dissimilar metals (electrically in contact and simultaneously exposed to an electrically conductive liquid) can occur, and corrosion is thus prevented.

It is important, therefore, that the Ground conductor from the Shore connection is NOT CONNECTED to the Power Inlet housing nor the Isolation Transformer enclosure PE (except temporarily when in dry-dock). On the floating AC output of the Isotransformer, it is possible to jumper a Neutral-Ground bond for allowing GCFI/RCD breakers onboard.

Warning: Never disconnect the shore Ground (PE) conductor unless you use an Isotransformer. Because GCFI/ RCD will not trip, nor a fuse will blow in the case of a short circuit current to metal parts on a vehicle, always use an Isotransformer with Neutral-Ground bond on the secondary.

Spécifications du produit

NUMÉRO D'ARTICLE
61224200 Isotransformer 2000
DONNÉES SUR LES VENTS
Rated power 2.0 kVA
Rated input voltage 240 V or 120 V
Rated output voltage 240 V or 120 V
Rated frequency 50 Hz / 60 Hz
Nominal current 8 A / 16 A
Circuit Breaker 12 A / (effectively 24 A for 120 V)
Inrush current Soft start included
Transformer type Toroidal (low noise, low weight)
GÉNÉRALE
No load consumption less than 10 W
Ambient operating temperature -10°C .. +45°C, derating above 45°C
Storage temperature -25°C to 85°C
Operating humidity 95% max, non-condensing
Audible noise <40.0 dB(A); <54dB(A) with forced cooling
Local user interface None
Weight <12.5 kg
Dimensions (HxWxD) 432 x 213 x 128 mm
PROTECTIONS
Overcurrent, short circuit Circuit Breaker included
Temperature protection Automatic switch off if transformer core > 120°C
Overvoltage protection Soft start is protected for overvoltage using fuse
Safety Standards IEC 60079, IEC 60726
MÉCANIQUE
Protection degree IP21
Connections input/output 6 mm2 max.
Cable gland entry 16 mm
Mounting holes M6
Enclosure construction Aluminum sheet metal
Surface finishing RAL9010 white + AE80104123621 black