Supreme 12 VDC – 40 A

Meet the Supreme 12 VDC – 40 A battery charger with multiple outputs. Ideal for installation in automotive, marine environments and more. Capability to charge up to three batteries. Easy to configure for AGM, GEL, Lead-acid and Lithium types. Worldwide usability is assured, as Supreme charging stations handle input voltages from 90 to 265 VAC (50/60 Hz).

  • Complies with CE and ABYC standards
  • Designed to charge three independent batteries (suitable for 1 or 2)
  • Batteries can differ in capacity (Ah)
  • Programmable for AGM, GEL, Lead acid and Lithium batteries
  • Temperature sensor protects against risk of gas production
  • Automatically adjusts supply voltage for worldwide use (90-265 VAC)
  • Works with small gasoline or diesel generators
61112304 system example1

Benefits of the Supreme 12 VDC – 40 A

  • Fast charge even with low input voltage
  • Each output can be programmed differently
  • Battery connection easily accessible, AC power cord supplied
  • Quick install
  • Quiet – no hum from transformer
  • Maximizes battery lifetime
  • Outstanding price – performance ratio

Product specifications

ARTICLE NUMBER
61112304 Supreme 12 VDC - 40 A
DIMENSIONS & WEIGHT
Weight 2.6 Kg / 5.7 lb.
Length x width x height, mm (in.) 295 x 206 x 86 (11.6 x 8.1 x 3.4)
TECHNICAL SPECIFICATIONS
Output Current (Maximum) 40 A
Output Voltage Charge 14.2 - 15.5 V
Output Voltage Float 13.4 - 13.8 V
Output Voltage Equalize 16.0 V
Charging Control 3-step (Bulk / Absorption / Float)
DC Output Bank 3
Selectable Battery Type GEL, AGM, WET, Lithium
Parasitic Current < 2 mA
CHARGER INPUT
AC Input Voltage (Nominal) 100, 120, 220, 230, 240 VAC
AC Input Operating Range 90 - 265 VAC
AC Input Frequency Range 47 - 63 Hz
Power Consumption (Full Load) 700 W
Power Factor Correction Yes
Charger Efficiency > 82%
PROTECTION AND FEATURES
Reverse Battery Yes, unit shutdown
Over Charge Yes, unit shutdown
Over Heating Yes, unit de-rated and shutdown
Output Short Circuit Yes, unit shutdown
Cooling Forced air ventilation
Temperature Setting Hot, Normal, Cold (no sensor connected)
Battery Temperature Sensor Yes included with 1.5 mtr cable
Battery Temperature Sensor Port RJ12 (battery temp. sensor use)
Digital Display Port RJ12 (optional display panel use)
DISPLAY
LCD Display (with back lighting) Charging status, Battery Voltage
Warning and Fault Code A01-02, E01-09
AC INPUT AND DC OUTPUT CONNECTION
AC Input Connection Hardwire or AC Cord
DC Output Connection Heavy Duty Studs (3 banks)
DC Output Ground Single Heavy Duty Common Ground Stud
ENVIRONMENTAL AND OPERATING TEMPERATURE
Storage Range -40° to 70°C
Operating Range -20° to 60°C
Humidity 5-95%, RH non-condensing
Ingress Protection IP32