Product specifications
| ARTICLE NUMBER | |
|---|---|
| 60201405 | PMG frame 1 - 230 VAC | 50 Hz |
| 60201415 | PMG frame 1 - 120 VAC | 60 Hz |
| DIMENSIONS & WEIGHT | |
|---|---|
| Weight | 7.6 kg | 16.8 lb |
| Dimensions (h x w x d) mm | 436 × 207 × 151 |
| Dimensions (h x w x d) inch | 17.2 x 8.1 x 5.9 |
| GENERAL SPECIFICATIONS | |
|---|---|
| Output voltage (230 VAC version) | 200 .. 240 VAC (nominal 230 V) |
| Output current (230 VAC version) | 28 A |
| Nominal power (230 VAC version) | 6 kVA |
| Output voltage (120 VAC version) | 105 .. 125 VAC (nominal 120 V) |
| Output current (120 VAC version) | 33 A |
| Nominal power (120 VAC version) | 3.5 kVA |
| Output load | True sine |
| Output voltage stability | +/- 5% (resistive load step 0 .. 100%) |
| Frequency variations | < 1% |
| Nominal efficiency (@ full load) | 95% |
| Peak efficiency | 97% |
| Input voltage | 3 times 260 .. 400 VAC |
| Input frequency | 200 .. 400 Hz |
| TECHNICAL SPECIFICATIONS | |
|---|---|
| Voltage THD (Total Harmonic Distortion) | < 5% |
| Short circuit protection | Yes |
| Mean time between failure | 10 years |
| Lifetime expectancy (@ 40°C and nominal load) | 100,000 hours |
| Local read out module | Inverter status load bar, voltage and runtime indicator (for maintenance purposes) and failure notification |
| Remote panel (LED) | Inverter status load bar, voltage indicator, AC input present and failure notification |
| USB | For software parameter configuration |
| Potential-free status contact | Inverter enabled / disabled |
| Wire system | L1 - N - PE |
| Recommended cable cross input / protection fuse | 4mm 2 / 32 A |
| Recommended cable cross output / protection fuse | 4mm 2 / 32 A RCD |
| Remote panel connection | RJ12 twisted cable (max. 15m) |
| Engine interface connection | Engine RPM request (pwm signal; optimal) |
| OPERATING CONDITIONS | |
|---|---|
| Operating temperature | -20 .. 70°C (linear derating above 40°C) |
| Storage temperature | -40 .. 80°C |
| Relative humidity in operation/storage | Max. 95% non-condensing |
| Protection degree | IP23 |
| Ventilation | Forced cooling |
| CONFORMITY | |
|---|---|
| Compliance | Directives: EMC 2004/108/EC, LVD 2006/95/EC, Standards: EN 55022 (emission), EN 61000-3-2 (harmonics), EN 61000-4-11, EN 61000-6-1, EN 61000-6-1 (immunity), EN 60945 (maritime navigation and radiocommunication), EN 60950 (safety) |